Max Caddy

Model: #PF01102

Brand: Caddy

PSG's largest furnace is now even smarter, with a new electronic platform that facilitates intersystem connections and makes the Max Caddy a natural choice as a core component of your whole home heating and cooling system.

Max Caddy's new streamlined electronic platform makes it easy for different systems to talk to each other. Heat pumps, air conditioners, humidifiers—the Max Caddy easily communicates with all of these appliances using standard industry symbols and practices. Easy-to-identify input and output ports and a blower assembly with prewired main board simplify installation and hookup. And PSG's touchscreen LCD control module makes input and output control a breeze.

The Max Caddy's integrated control PC board and RTD probe automatically ensures that the furnace blower is operating at optimum speed, keeping the plenum at just the right temperature. The built-in heat exchanger system ensures that heat is transferred quickly and efficiently via the smoke ducts inside the furnace instead of being lost up the chimney. The result is superior comfort and energy efficiency, with savings of up to 30% on firewood and reductions in particulate emissions up to 80%.

Performance

Scroll
Fuel Type Dry cordwood
Recommended heating area (sq.ft.) 1,500 - 3,500
Firebox nominal volume (cu. ft.) 4.9
Maximum burn time 17 h
Maximum input capacity (dry cordwood) 421,000 BTU
Overall heat output rate (min. to max.) 18,424 BTU/h (5.6 kW) to 66,576 BTU/h (19.6 kW)
Average overall efficiency (min. to max.) 78.90% (HHV)
85.8% (LHV)
Delivered heat output rate (min. to max.) 5,118 BTU/h (4.7 kW) to 51,241 BTU/h (16 kW)
Average delivered efficiency (min. to max.) 64.80% (HHV)
70.20% (LHV)
Optimum efficiency 85.80%
Average particulate emissions rate 0.753 lb/mmBTU (0.326 g/MJ)
Average CO 12.20 lb/mmBTU (5.25 g/MJ)
Average electrical power consumption 360 W

General Features

High-efficiency EPA certified appliance CSA B415.1-10
Maximum log length 25"
Log positioning Over depth
Chimney diameter 6"
Flue outlet diameter 6"
Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
Baffle type C-Cast
Approved for an alcove installation No
Approved for a mobile home installation No
Shipping Weight 729 lb (331 kg)
Door type Single, glass with cast iron frame
Glass type Ceramic glass
Glass surface – dimensions (Width X Height) 14 1/2" X 10 1/8"
Glass air-wash system Yes
Blower (hp / speed / CFM) 1/2 / 4 / 2,100
Filter – dimensions (Width X Height X Depth) 16" X 20" X 1"
Overall dimension (Height) 50 1/2"
Overall dimension (Width) 36 1/4"
Overall dimension (Depth) 60 1/8"
Door opening – dimension (Height) 9 7/8"
Door opening - dimension (Width) 15 3/4"
Firebox – dimension (Height) 15 7/8"
Firebox – dimension (Width) 20 3/8"
Firebox – dimension (Depth) 26 1/4"
Firebox lined with refractory bricks for better heat distribution Yes
Stainless-steel secondary-air system improving gas combustion Yes
Adjustable threaded legs Yes
Steel thickness – body 3/16"
Steel thickness – top 1/4"
Easy-to-access ash drawer Yes
Air return plenum – dimension (Depth or Height) 17 7/8"
Air return plenum – dimension (Width) 19 7/8"
Hot air plenum – dimension (Depth or Height) 32 1/8"
Hot air plenum – dimension (Width) 25 3/8"
Burner – standard Beckett - AFG
Burner – other brand approved Riello
Burner – location Right or left
Burner – efficiency at input #1 85 % (Beckett)
Burner – recommended connector pipe diameter (Wood-oil) 7"
Burner – recommended exhaust pipe diameter 5"
Burner – location of exhaust pipe Right or left
Burner – capacity at input #1 90,000 BTU (26.4 kW)
Burner – orifice at input #1 0.55 X 60°W (Beckett)
Burner – pump pressure at input #1 140 psi (Beckett)
Electric element – location Right or left
Burner – recommended clearance for maintenance 24"
Electric element – recommended (maximum output) 20 kW
Electric element – other optional (maximum output) 25 kW
Water loop kit – connection location 3/4"
Water loop kit – back-up tank volume 60 gal (227 L)
USA standard (emissions) EPA (CSA B415.1-10)
Canadian Standard (emissions) CSA B415.1-10
USA standard (safety) UL 1995, UL 727, UL 391
Canadian standard (safety) CSA B366.1, CSA C22.2 no 236, CAN/CSA B140.4 CSA B212-93
Tested and listed as per applicable standards By an accredited laboratory (CAN/USA)
Warranty Limited lifetime

Minimum clearances to combustibles

(Data expressed in inches. 1 inch = 25.4 mm)

Canada United States
Clearance – back wall 24" 24"
Clearance – ducts <6'=6" + protection ; >6'=1" <6'=6" + protection ; >6'=1"
Clearance – recommended for maintenance on option side 24" 24"
Clearance – front 48" 48"
Clearance – side wall 6" 6"
Clearance – opposite side wall 24" 24"
Clearance – top (measured from the platform on which the appliance is installed) 79" 79"