Laboom

Caddy

Model: #PF01015

Brand: Caddy

Advanced combustion technology and state-of-the-art design have earned the Caddy furnace a reputation as the cleanest, most efficient furnace ever produced by PSG—and with good reason! So how do you make a star product even better? With performance-enhancing electronics that take our flagship furnace to the next level.

The secret behind the Caddy's outstanding performance is its built-in heat exchanger system, which ensures that heat is transferred quickly and efficiently via the smoke ducts inside the furnace instead of being lost up the chimney. It uses up to 30% less firewood and reduces particulate emissions by as much as 80%. That's great news for your heating bill—and the environment!

With Caddy series furnaces, you'll always have an alternate source of heat to ensure the comfort and safety of your family. The Caddy comes in four different configurations: wood-only, wood+electric combo, wood+oil combo, and wood add-on furnace.

Performance

Scroll
Fuel Type Dry cordwood
Recommended heating area (sq.ft.) 1,000 - 2,500
Firebox nominal volume (cu. ft.) 3.6
Maximum burn time 15 h
Maximum input capacity (dry cordwood) 310,000 BTU
Overall heat output rate (min. to max.) 15,436 BTU/h (4.5 kW) to 49,638 BTU/h (14.5 kW)
Average overall efficiency (min. to max.) 76.70% (HHV)
82.90% (LHV)
Delivered heat output rate (min. to max.) 12,635 BTU/h (3.7 kW) to 44,857 BTU/h (13.1 kW)
Average delivered efficiency (min. to max.) 62.70% (HHV)
68.30% (LHV)
Optimum efficiency 84.90%
Average particulate emissions rate 0.654 lb/mmBTU (0.282 g/MJ)
Average CO 11.18 lb/mmBTU (4.81 g/MJ)
Average electrical power consumption 432 W

General Features

High-efficiency EPA certified appliance CSA B415.1-10
Maximum log length 22"
Log positioning Over depth
Chimney diameter 6"
Flue outlet diameter 6"
Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
Baffle type C-Cast
Approved for an alcove installation No
Shipping Weight 576 lb (261 kg)
Door type Single, glass with cast iron frame
Glass type Ceramic glass
Glass surface – dimensions (Width X Height) 12 1/2" X 10 1/8"
Blower (hp / speed / CFM) 1/3 / 4 / 1,900
Filter – dimensions (Width X Height X Depth) 14" X 25" X 1"
Overall dimension (Height) 49"
Overall dimension (Width) 32 1/4"
Overall dimension (Depth) 52 7/8"
Door opening – dimension (Height) 10"
Door opening - dimension (Width) 13 3/4"
Firebox – dimension (Height) 16"
Firebox – dimension (Width) 17"
Firebox – dimension (Depth) 22 5/8"
Steel thickness – body 3/16"
Steel thickness – top 1/4"
Easy-to-access ash drawer Yes
Air return plenum – dimension (Depth or Height) 15 3/4"
Air return plenum – dimension (Width) 24 3/4"
Hot air plenum – dimension (Depth or Height) 28 5/8"
Hot air plenum – dimension (Width) 24 1/2"
Wood Add-on – location of the connection with the existing furnace Right or left
Burner – standard Beckett AFG
Burner – other brand approved Riello, Aero
Burner – location Right or left
Burner – recommended connector pipe diameter (Wood-oil) 7"
Burner – recommended exhaust pipe diameter 5"
Burner – location of exhaust pipe Right or left
Burner – capacity at input #1 90,000 BTU (26.4 kW)
Burner – orifice at input #1 0,55 X 60° W (Beckett)
Burner – pump pressure at input #1 140 psi
Burner – efficiency 85 % (Beckett)
Burner – recommended clearance for maintenance 24"
Electric element – location Right or left
Electric element – recommended (maximum output) 18 kW
Electric element – recommended clearance for maintenance 29"
Electric element – other optional (maximum output) 15 kW or 20 kW
USA standard (emissions) EPA (CSA B415.1-10)
Canadian Standard (emissions) CSA B415.1-10
USA standard (safety) UL 391, UL 1995, UL 727
Canadian standard (safety) CSA B366.1, CSA C22.2 no 236, CAN/CSA B140.4
Tested and listed as per applicable standards By an accredited laboratory (CAN/USA)
Warranty Limited lifetime

Minimum clearances to combustibles

(Data expressed in inches. 1 inch = 25.4 mm)

Canada United States
Clearance – back wall 24" 24"
Clearance – ducts <6'=6" ; >6'=1" <6'=6" ; >6'=1"
Clearance – recommended for maintenance on option side 24" 24"
Clearance – front 48" 48"
Clearance – side wall 6" 6"
Clearance – opposite side wall 24" 24"
Clearance – top (measured from the platform on which the appliance is installed) 72" 72"

Call Us

If you have any questions, or you're ready to place your order, give us a call at (440) 293-4622